NOTE: Use new gaskets and 0-rings when reassembling.
Testing
Replace thermostat if it is open at room temperature.
To test a closed thermostat: 1 . Suspend the thermostat in a container of water as shown. 2. Heat the water and check the temperature with a thermometer. Check the temperature at which the thermostat first opens and at full lift. CAUTION: Do not let the thermometer touch the bottom of the hot container.